CRT-TCC Temperature controlled cabinet for CRT-UTM-NU The temperature can be controlled to 0.2ºC over the range -25ºC to +60ºC using a PID digital temperature controller, the CAL3200. Forced air over the heater and cooling fins and through the air duct in the rear wall ensures a uniform temperature throughout the cabinet. Defrost water drains via a pipe on the back of the cabinet to a heated tray underneath the cabinet where the water will evaporate. The cabinet also features an over temperature device which will switch off the fans, heating, cooling and illuminates a warning light if the set temperature is exceeded. The front door is double-glazed and contains a heating element to ensure that the glass door remains clear. When testing asphalt good temperature control is essential. Test data shows that a 1% change in temperature can cause up to 10% variation in stiffness results. |
 |
CRT-IT-SET Test System Indirect tensile stiffness modulus measurement system to perform EN 12697-26 (Annex C)
- Sub-frame for 100mm and 150mm Ø specimens, Specimen alignment jig
- Loading strips and displacement transducer yoke for 100 & 150mm Ø specimens
- 2* CRT-ITLV AC LVDT displacement transducer ±0.25mm range
- CRT-CALCR. Calibration check ring for checking accuracy of load and displacement transducers used in Indirect Tensile Stiffness Modulus test
- Setup jig
- Crosshead with linear bearings
- 1* 7mm spanner
- Test software to meet latest standard specifications
|
 |
CRT-FAT-SET Indirect tensile fatigue measurement system to perform EN 12697-24 (Annex E)
- Requires CRT-IT-SET Sub-frame
- 2* CRT-SPTLVDT displacement transducer ±1.0mm range
- On specimen fatigue clamping frame for 100mm Ø specimens
- Setup jig
- 1* 7mm spanner
- Test software to meet latest standard specifications
|
 |
CRT-ITSMFAT-SET Indirect tensile stiffness modulus and fatigue measurement system to perform EN 12697-26 (Annex C) and EN 12697-24 (Annex E)
- Sub-frame for 100mm and 150mm Ø specimens
- Specimen alignment jig
- Loading strips and displacement transducer yoke for 100 & 150mm Ø specimens
- 2* CRT-ITLV AC LVDT displacement transducer ±0.25mm range
- CRT-CALCR. Calibration check ring for checking accuracy of load and displacement transducers used in Indirect Tensile Stiffness Modulus test
- 2* CRT-SPTLVDT displacement transducer ±1.0mm range
- On specimen fatigue clamping frame for 100mm Ø specimens
- Setup jig
- Crosshead with linear bearings
- 1* 7mm spanner
- Test software to meet latest standard specifications
|
 |
CRT-PD-SET Dynamic and static creep measurement system to perform EN12697-25 (Method A)
- 1* 100mm platens (top and bottom) with holders
- 1* 150mm platens (top and bottom) with holders
- 2* CRT-PDLV. AC LVDT displacement transducer ±5.0mm range
- Test software to meet latest standard specifications
|
 |
CRT-TP31 Resilient modulus test system to perform AASHTO TP31 and ASTM D4123 for 100mm and 150mm Ø samples up to 80mm thick
- Stainless steel test frame with guides to maintain upper and lower loading strips parallel
- 12.7 mm wide loading strips with contact faces shaped to fit 100mm Ø specimens
- 19.0 mm wide loading strips with contact faces shaped to fit 150mm Ø specimens
- Machined tolerances +/- 0.1mm and +/- 0.01mm where parts are mating.
- 2* CRT-ITLV AC LVDT displacement transducer ±0.25mm range
- 2* CRT-SPTLVDT displacement transducer ±1.0mm range
- Brass and steel LVDT clamps and adjusters for vertical and horizontal diametral measurement
- CRT-CALCR Calibration check ring for checking accuracy of load and displacement transducers used in Indirect Tensile Stiffness Modulus test.
- Integral LVDT yoke
- LVDT adjusters
- Test software to meet latest standard specifications
- Haversine load pulses at standard frequencies
- Applies required load for selected number of load applications
- Captures outputs from load and displacement transducers
- Calculates maximum load, recoverable deformation, Poisson's ratio and resilient modulus
|
 |
CRT-T307 Triaxial system to perform AASHTO T307 for 200mm high x 100mm Ø specimens of unbound materials
- Triaxial cell with internally mounted load cell. Base adaptor with no-volume change valves
- Pressure range 0-500kPa
- Machined tolerances +/- 0.1mm and +/- 0.01mm where parts are mating
- Pneumatic system with vacuum for specimen set-up and software controllable cell pressure
- 100mm membrane stretcher
- Pressure transducer
- LVDTs to meet test specification
- Hard rubber dummy specimen
- Porous top cap
- 2* Porous discs
- 3* ‘O' rings for sealing 100mm membranes
- Cell pressurisation system including digitally controlled voltage pressure converter, pressure transducer, vacuum source and vacuum adjustment
- 3* Rubber membranes for 100mm Ø specimens
- Test software to meet latest standard specifications
|
| |
CRT-UNIVSOFT Facilitates the design of test routines that can include multiple wave types, test stages and methods of data acquisition. |
| |
CRT-COMP-650 Standard air compressor (up to 7bar and 600 L/m) for supply of air to CRT-UTM-NU |
| |
CRT-FT06-AIRDRYER Air dryer with 600 L/s flow rate and 3°C dew point |
 |
CRT-PRESTRIAX-SET Dynamic and static creep measurement system with confining stress to perform EN 12697-25 (Method B)
- System to produce adjustable confining stress 100mm and 150mm Ø specimens in axial tension or compression
- Triaxial cell with accurate pressure regulator, pressure indicator and all pneumatic fittings
- Pressure range 0-500kPa
- 100mm Ø platens with ‘O' rings for sealing membranes
- 150mm Ø platens with ‘O' rings for sealing membranes
- Platens are M.S. grade 070M20 case hardened to 750HV to a depth after grinding of at least 0.5mm. They are surface ground and polished.
- 2* CRT-PDLV. Permanent deformation displacement transducer ±5.0mm range
- 3* 100mm Ø x 100mm neoprene membranes
- 3* 150mm Ø x 200mm neoprene membranes
- Test software to meet latest standard specifications
|
 |
CRT-SPTLV Test system to perform dynamic modulus according to AASHTO TP62 / Simple Performance Test
- 2* Clip-on CRT-SPTLVDT displacement transducer ±1.0mm range
- 4* Clip-on LVDT holders, 24 targets
- LVDT stud placer unit
- LVDT stud placer top plate
- 1* upper platen 100 SPT
- 1* lower platen 100 SPT
- 2* 100mm dia. X 0.5 PTFE disc
- 1* araldite glue
- Pneumatic fittings
- Test software to perform Dynamic modulus for permanent deformation
|